OUR PRODUCTS

Go for the best brands of hydronic heating products on the market! We provide a range of products and highly superior operational and energy efficient components. Our selection is tailored to residential and commercial installation of contractors’ and suppliers’ hydronic heating equipment.

All products

Commercial installation

  • Squire

    ,

    The Squire Stainless Steel Indirect Water Heater — with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to fit your application.

    Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat exchanger, two inch thick, high-density insulating foam, and best of all it is designed, engineered and assembled in America.

    • – 12 models: 30-199 Gallons
    • – 316L Passivated stainless steel tank
    • – High capacity stainless steel coil
    • – Fully welded construction
    The supplier
  • Lock-Temp® Tank

    Lochinvar’s glass lined, jacketed and insulated hot water storage tanks have been specifically engineered and constructed to provide a high volume supply of hot water at a constant outlet temperature. The unique Lock-Temp® baffle design is so effective that 80% of the storage volume can be utilized at the stored water temperature, regardless of the rate of outlet water flow

    • – ASME Section IV construction
    • – Capacities from 80-2,500 gallons
    • – Glass or cement lining options
    • – Standard magnesium anode rods
    • – Five-Year limited warranty
    The supplier
  • CON·X·US

    Control from anywhere!

    From wherever you are, the CON·X·US option lets you use any Internet-capable device to link up with any SMART SYSTEM branded control on an unlimited number of applicable units. With CON·X·US, you’re always in touch and in control. Do regular CON·X·US checks for all your customers, and let them know you’re monitoring their unit’s performance.

    • · Adjust setpoints, domestic hot water, reset curves, pump delays and more, using the CON·X·US interactive display
    • · Status alerts via text or e-mail let you know when equipment needs attention
    The supplier
  • Chaudiere Vapeur Sans Tube Lattner

    VERTICAL TUBELESS STEAM BOILER

    The vertical efficient, four-pass, compact and tubeless steam Lattner boiler will let you make your steam easier and faster. This product is perfect for dry cleaning, laundry apparel, humidification, sterilization manufacturing and commercial processes, health and exercise clubs, steam rooms and food preparation and processing.

    The supplier
  • VIC

    VIC – CONDENSING VENT

    Appplications

    ICC Model VIC is a tested single wall, double wall, or insulated double wall vent system for condensing or near condensing appliances. Tested and listed to : UL 1738 / ULC S636. ICC Condensing Vent can be used in the following applications:

    • – Category I, II, III and IV gas fired appliances producing a maximum flue gas temperature of 550°F.
    • – BH gas vent for appliances producing a maximum flue gas temperature of 550°F.
    • – Appliances that produce condensation in the exhaust stream.
    Construction

    VIC’s inner liner is constructed of either super ferritic type AL29-4C stainless steel or out of type 444 stainless steel. Both alloys meet the requirements of the UL corrosion resistance test. When a double wall system is specified, the outer casing will be made of a type 430 stainless steel.

    The inner liner of 5in to 16in diameter VIC is either Tungsten Arc Welded or Laser welded. Diameters 18in to 24in are Tungsten Arc Welded. Both Laser and Tungsten Arc welds are butt welds. Butt welding minimizes the impact on the steel, resulting in a smooth and corrosion resistant seam.

    The system is available in the following configurations:

    • – Single wall – for breeching and connecting multiple appliances together. It is lightweight and easy to install. It is recommended that single wall VIC be installed inside the building or where ambient temperatures remain above freezing.
    • – Double wall – improves heat retention in the flue. This increases draft strength and can reduce clearance to combustibles in some cases. Double wall also has a lower impact on the surrounding environment’s temperature (e.g. mechanical room). It is approved for interior and exterior installations.
    • – Double wall insulated – the best choice for exterior installations in cold weather climates. The insulated casing minimizes heat loss and promotes increased draft.
    Installation

    VIC incorporates a silicone gasket which creates a seal that is both gas and water tight. The silicone seal drastically reduces installation time by eliminating the need for sealant to be applied in the field. VIC locking bands hold the sections together without the need of additional screws. The captive nut / bolt system is exceptionally strong and results in a straight, secure run of pipe.

    Technical sheet The supplier